Three Phase PV String Inverter 17-30 kW Low-voltage Series
BNT017-30-KTA
The Afore Three-phase string inverters Low-voltage series are designed for commercial and power plant pV system applications, rating from 17kW to 30kW. All models with aluminum housings which is anodized, increasing durability and effectively prevents corrosion. Equipped with external inductors, ensureefficient heat dissipation, which significantly improves the reliability and extends the life of the inverters.
MPPT efficiency > 99.9%
Intelligent Temperature Control System
Active and reactive power compensation, adjust power factor
IP 68 Cooling Fan
Type ll DC & AC lightning protection
AC output 1.1x continuous operation
Product introduction
MAX.20Adc
String Current Up To 20A
PV OVERSIZE
Max. 1.5 Time PV Oversize input
PROTECTION
Multiple intelligent Protections
ANTI-FLOW
Anti-Feed-in Function
Wi-Fi
Wi-Fi Standard, Ethernet/GPRS Optional
CONFIGURATION
Quick & Easy Config. via Wi-Fi
MODBUS
MODBUS
Communication Ready
Technical Data | BNT017KTA | BNT020KTA | BNT025KTA | BNT030KTA |
---|---|---|---|---|
PV Input Data | ||||
Max. DC Power (W) | 25500 | 30000 | 37500 | 45000 |
Max. DC Voltage V) | 750 | 750 | 750 | 750 |
MPPT Voltage Range (V) | 200-700 | 200-700 | 200-700 | 200-700 |
MPPT Full Power Voltage Range (V) | 310-600 | 320-600 | 300-600 | 300-600 |
Rated Input Voltage(V) | 400 | 400 | 400 | 400 |
Start-up Voltage (V) | 150 | 150 | 200 | 200 |
Max.Input Current (A) | 38x2 | 38x3 | 40x3 | 38x4 |
Max.Short Current(A) | 48x2 | 48x3 | 48x3 | 48x4 |
No.of MPP Tracker/ No. of PV String | 2/5 | 3/6 | 3/7 | 4/8 |
Input Connector Type | MC4 | MC4 | MC4 | MC4 |
AC Output Data | ||||
Max. Output Power (VA) | 18700 | 22000 | 27500 | 33000 |
Nominal Output Power(W) | 17000 | 20000 | 25000 | 30000 |
Max. Output Current (A) | 48 | 60 | 80 | 96 |
Nominal Output Voltage (V) | 3P+N+PE/3P+PE 133/220 or 230 | 3P+N+PE/3P+PE 133/220 or 230 | 3P+N+PE/3P+PE 133/220 or 230 | 3P+N+PE/3P+PE 133/220 or 230 |
Grid Voltage Range | 180-260Vac (According to local standard) | 180-260Vac (According to local standard) | 180-260Vac (According to local standard) | 180-260Vac (According to local standard) |
Nominal Output Frequency(Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
Grid Frequency Range | 45-55 /55-65Hz (According to local standard) | 45-55 /55-65Hz (According to local standard) | 45-55 /55-65Hz (According to local standard) | 45-55 /55-65Hz (According to local standard) |
Output Power Factor | 1 default (adjustable from 0.8 leading to 0.8 lagging) | 1 default (adjustable from 0.8 leading to 0.8 lagging) | 1 default (adjustable from 0.8 leading to 0.8 lagging) | 1 default (adjustable from 0.8 leading to 0.8 lagging) |
Output Current THD | <3% | <3% | <3% | <3% |
Efficiency | ||||
Max. Efficiency | 98.40% | 98.40% | 98.40% | 98.40% |
Euro Efficiency | 98.00% | 98.10% | 98.10% | 98.10% |
Protection | ||||
PV Reverse Polarity Protection | YES | YES | YES | YES |
PV Insulation Resistance Detection | YES | YES | YES | YES |
AC Short Circuit Protection | YES | YES | YES | YES |
AC Over Current Protection | YES | YES | YES | YES |
AC Over Voltage Protection | YES | YES | YES | YES |
Anti-Islanding Protection | YES | YES | YES | YES |
Residual Current Detection | YES | YES | YES | YES |
Over Temperature Protection | YES | YES | YES | YES |
Integrated DC switch | YES | YES | YES | YES |
Surge Protection | Integrated(Type II) | Integrated(Type II) | Integrated(Type II) | Integrated(Type II) |
General Data | ||||
Dimensions(Wx Hx D,mm) | 450x 485x210 | 710x470x236 | 710x470x236 | 710x470x236 |
Weight(kg) | 26 | 44 | 44 | 51 |
Protection Degree | IP 65 | IP 65 | IP 65 | IP 65 |
Enclosure Material | Aluminum | Aluminum | Aluminum | Aluminum |
Ambient Temperature Range (℃) | -25-+60 | -25-+60 | -25-+60 | -25-+60 |
Humidity Range | 0-100% | 0-100% | 0-100% | 0-100% |
Topology | Transformerless | Transformerless | Transformerless | Transformerless |
Communication Interface | RS485/WiFi/Wire Ethernet/ GPRS (optional) | RS485/WiFi/Wire Ethernet/ GPRS (optional) | RS485/WiFi/Wire Ethernet/ GPRS (optional) | RS485/WiFi/Wire Ethernet/ GPRS (optional) |
Cooling Concept | Intelligent Fan Cooling | Intelligent Fan Cooling | Intelligent Fan Cooling | Intelligent Fan Cooling |
Night Power Consumption(W) | <1 | <1 | <1 | <1 |
Max. Operation Altitude(m) | 2000 | 2000 | 2000 | 2000 |
Certifications and Standards | ||||
EMC Standard | EN/IEC 61000-6-2,EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 | EN/IEC 61000-6-2,EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 | EN/IEC 61000-6-2,EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 | EN/IEC 61000-6-2,EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 |
Safety Standard | IEC 60068, UL1741, EN62109 | IEC 60068, UL1741, EN62109 | IEC 60068, UL1741, EN62109 | IEC 60068, UL1741, EN62109 |
Grid-connection | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727 | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727 | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727 | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727 |