Three Phase PV String Inverter 17-30 kW Low-voltage Series

Description

The Afore Three-phase string inverters Low-voltage series are designed for commercial and power plant pV system applications, rating from 17kW to 30kW. All models with aluminum housings which is anodized, increasing durability and effectively prevents corrosion. Equipped with external inductors, ensureefficient heat dissipation, which significantly improves the reliability and extends the life of the inverters.

MPPT efficiency > 99.9%

Intelligent Temperature Control System

Active and reactive power compensation, adjust power factor

IP 68 Cooling Fan

Type ll DC & AC lightning protection

AC output 1.1x continuous operation

Product introduction

MAX.20Adc

String Current Up To 20A

PV OVERSIZE

Max. 1.5 Time PV Oversize input

PROTECTION

Multiple intelligent Protections

ANTI-FLOW

Anti-Feed-in Function

Wi-Fi

Wi-Fi Standard, Ethernet/GPRS Optional

CONFIGURATION

Quick & Easy Config. via Wi-Fi

MODBUS

MODBUS
Communication Ready

Technical DataBNT017KTABNT020KTABNT025KTABNT030KTA
PV Input Data
Max. DC Power (W)25500300003750045000
Max. DC Voltage V)750750750750
MPPT Voltage Range (V)200-700200-700200-700200-700
MPPT Full Power Voltage Range (V)310-600320-600300-600300-600
Rated Input Voltage(V)400400400400
Start-up Voltage (V)150150200200
Max.Input Current (A)38x238x340x338x4
Max.Short Current(A)48x248x348x348x4
No.of MPP Tracker/ No. of PV String2/53/63/74/8
Input Connector TypeMC4MC4MC4MC4
AC Output Data
Max. Output Power (VA)18700220002750033000
Nominal Output Power(W)17000200002500030000
Max. Output Current (A)48608096
Nominal Output Voltage (V)3P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 230
Grid Voltage Range180-260Vac (According to local standard)180-260Vac (According to local standard)180-260Vac (According to local standard)180-260Vac (According to local standard)
Nominal Output Frequency(Hz)50/6050/6050/6050/60
Grid Frequency Range45-55 /55-65Hz (According to local standard)45-55 /55-65Hz (According to local standard)45-55 /55-65Hz (According to local standard)45-55 /55-65Hz (According to local standard)
Output Power Factor1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)
Output Current THD<3%<3%<3%<3%
Efficiency
Max. Efficiency98.40%98.40%98.40%98.40%
Euro Efficiency98.00%98.10%98.10%98.10%
Protection
PV Reverse Polarity ProtectionYESYESYESYES
PV Insulation Resistance DetectionYESYESYESYES
AC Short Circuit ProtectionYESYESYESYES
AC Over Current ProtectionYESYESYESYES
AC Over Voltage ProtectionYESYESYESYES
Anti-Islanding ProtectionYESYESYESYES
Residual Current DetectionYESYESYESYES
Over Temperature ProtectionYESYESYESYES
Integrated DC switchYESYESYESYES
Surge ProtectionIntegrated(Type II)Integrated(Type II)Integrated(Type II)Integrated(Type II)
General Data
Dimensions(Wx Hx D,mm)450x 485x210710x470x236710x470x236710x470x236
Weight(kg)26444451
Protection DegreeIP 65IP 65IP 65IP 65
Enclosure MaterialAluminumAluminumAluminumAluminum
Ambient Temperature Range (℃)-25-+60-25-+60-25-+60-25-+60
Humidity Range0-100%0-100%0-100%0-100%
TopologyTransformerlessTransformerlessTransformerlessTransformerless
Communication InterfaceRS485/WiFi/Wire Ethernet/ GPRS (optional)RS485/WiFi/Wire Ethernet/ GPRS (optional)RS485/WiFi/Wire Ethernet/ GPRS (optional)RS485/WiFi/Wire Ethernet/ GPRS (optional)
Cooling ConceptIntelligent Fan CoolingIntelligent Fan CoolingIntelligent Fan CoolingIntelligent Fan Cooling
Night Power Consumption(W)<1<1<1<1
Max. Operation Altitude(m)2000200020002000
Certifications and Standards
EMC StandardEN/IEC 61000-6-2,EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2,EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2,EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2,EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12
Safety StandardIEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109
Grid-connectionIEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727