Technical Data | AF4K-SLP | AF4.6K-SLP | AF5K-SLP | AF5.5K-SLP | AF6K-SLP |
---|---|---|---|---|---|
PV Input | |||||
Max.Input Power (kW) | 6 | 6.9 | 7.5 | 8.3 | 9 |
Max. PV Voltage (V) | 550 | 550 | 550 | 550 | 550 |
MPPT Range (V) | 80-500 | 80-500 | 80-500 | 80-500 | 80-500 |
Full MPPT Range (V) | 120-500 | 130-500 | 150-500 | 160-500 | 170-500 |
Normal Voltage (V) | 360 | 360 | 360 | 360 | 360 |
Startup Voltage (V) | 100 | 100 | 100 | 100 | 100 |
Max. Input Current (A) | 18.5x2 | 18.5x2 | 18.5x2 | 18.5x2 | 18.5x2 |
Max.Short Current (A) | 26x2 | 26x2 | 26x2 | 26x2 | 26x2 |
No.of MPP Tracker / No. of PV String | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 |
Battery Port | |||||
Max.Charge/Discharge Power (kW) | 4.0 | 4.6 | 5.0 | 5.5 | 6.0 |
Max.Charge/Discharge Current (A) | 120 | 120 | 120 | 120 | 120 |
Battery Normal Voltage (V) | 51.2 | 51.2 | 51.2 | 51.2 | 51.2 |
Battery Voltage Range (V) | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 |
Battery Type | Li-ion / Lead-acid etc. | Li-ion / Lead-acid etc. | Li-ion / Lead-acid etc. | Li-ion / Lead-acid etc. | Li-ion / Lead-acid etc. |
AC Grid | |||||
Max Continuous Current (A) | 19.0 | 22.0 | 23.0 | 26.0 | 28.0 |
Max Continuous Power (kVA) | 4.0 | 4.6 | 5.0 | 5.5 | 6.0 |
Nominal Grid Current (A) | 18.2/17.4 | 21.0/20.0 | 22.8/21.8 | 25.0/24.0 | 27.3/26.1 |
Nominal Grid Voltage (V) | 198 to 242 @220/ 207 to 253@ 230 | 198 to 242 @220/ 207 to 253@ 230 | 198 to 242 @220/ 207 to 253@ 230 | 198 to 242 @220/ 207 to 253@ 230 | 198 to 242 @220/ 207 to 253@ 230 |
Nominal Grid Frequency(Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Power Factor | 0.999 (Adjustable from 0.8 overexcited to 0.8 underexcited) | 0.999 (Adjustable from 0.8 overexcited to 0.8 underexcited) | 0.999 (Adjustable from 0.8 overexcited to 0.8 underexcited) | 0.999 (Adjustable from 0.8 overexcited to 0.8 underexcited) | 0.999 (Adjustable from 0.8 overexcited to 0.8 underexcited) |
Current THD (%) | <3 | <3 | <3 | <3 | <3 |
AC Load Output | |||||
Max Continuous Current (A) | 19.0 | 22.0 | 23.0 | 26.0 | 28.0 |
Max Continuous Power (kVA) | 4.0 | 4.6 | 5.0 | 5.5 | 6.0 |
Max Peak Current (A) (10min) | 27.3/2 | 6.1 31.4/30 | 34.1/32.7 | 37.8/36.1 | 41.0/39.2 |
Max Peak Power (kVA) (10min) | 6.0 | 6.9 | 7.5 | 8.3 | 9.0 |
Nominal AC Voltage L-N (V) | 220/230 | 220/230 | 220/230 | 220/230 | 220/230 |
Nominal AC Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Switching Time (ms) | Seamless | Seamless | Seamless | Seamless | Seamless |
Voltage THD (%) | <3 | <3 | <3 | <3 | <3 |
Efficiency | |||||
CEC Efficiency (%) | 97.0 | 97.0 | 97.0 | 97.0 | 97.0 |
Max. Efficiency (%) | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 |
PV to Bat. Efficiency (%) | 98.1 | 98.1 | 98.1 | 98.1 | 98.1 |
Bat. between AC Efficiency (%) | 96.8 | 96.8 | 96.8 | 96.8 | 96.8 |
Protection | |||||
PV Reverse Polarity Protection | Yes | Yes | Yes | Yes | Yes |
Over Current/Voltage Protection | Yes | Yes | Yes | Yes | Yes |
Anti-Islanding Protection | Yes | Yes | Yes | Yes | Yes |
AC Short Ciruit Protection | Yes | Yes | Yes | Yes | Yes |
Residual Current Detection | Yes | Yes | Yes | Yes | Yes |
Ground Fault Monitoring | Yes | Yes | Yes | Yes | Yes |
Insulation Resister Detection | Yes | Yes | Yes | Yes | Yes |
PV ArcDetection | Yes | Yes | Yes | Yes | Yes |
Enclosure Protect Level | IP65 / NEMA4X | IP65 / NEMA4X | IP65 / NEMA4X | IP65 / NEMA4X | IP65 / NEMA4X |
AC/DC surge protection | Type II | Type II | Type II | Type II | Type II |
General Data | |||||
Dimensions (WxHxD,mm) | 370x535x192 | 370x535x192 | 370x535x192 | 370x535x192 | 370x535x192 |
Weight(kg) | 20.5 | 20.5 | 20.5 | 20.5 | 20.5 |
Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless |
Cooling | Intelligent Fan | Intelligent Fan | Intelligent Fan | Intelligent Fan | Intelligent Fan |
Relative Humidity | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
Operating Temperature Range (℃) | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 |
Operating Altitude (m) | <4000 | <4000 | <4000 | <4000 | <4000 |
Standby Consumption (W) | <10 | <10 | <10 | <10 | <10 |
Mounting | Wall Bracket | Wall Bracket | Wall Bracket | Wall Bracket | Wall Bracket |
Communication with RSD | SUNSPEC | SUNSPEC | SUNSPEC | SUNSPEC | SUNSPEC |
Display & Communication Interfaces | LCD LED, RS485 CAN Wi-Fi GPRS 4G | LCD LED, RS485 CAN Wi-Fi GPRS 4G | LCD LED, RS485 CAN Wi-Fi GPRS 4G | LCD LED, RS485 CAN Wi-Fi GPRS 4G | LCD LED, RS485 CAN Wi-Fi GPRS 4G |
Certification & Approvals | NRS097 G98 EN50549-1 C10/C11 AS4777.2 VDE-AR-N4105 VDE0126 IEC62109-1 IEC62109-2 | NRS097 G98 EN50549-1 C10/C11 AS4777.2 VDE-AR-N4105 VDE0126 IEC62109-1 IEC62109-2 | NRS097 G98 EN50549-1 C10/C11 AS4777.2 VDE-AR-N4105 VDE0126 IEC62109-1 IEC62109-2 | NRS097 G98 EN50549-1 C10/C11 AS4777.2 VDE-AR-N4105 VDE0126 IEC62109-1 IEC62109-2 | NRS097 G98 EN50549-1 C10/C11 AS4777.2 VDE-AR-N4105 VDE0126 IEC62109-1 IEC62109-2 |
EMC | EN61000-6-2 EN61000-6-3 | EN61000-6-2 EN61000-6-3 | EN61000-6-2 EN61000-6-3 | EN61000-6-2 EN61000-6-3 | EN61000-6-2 EN61000-6-3 |