Three Phase PV String Inverter 3-15 kW Low-voltage Series

Description

The Afore Three-phase string inverters Low-voltage series are designed for commercial and power plant pV system applications, rating from 3kW to 15kW. All models with aluminum housings which is anodized, increasing durability and effectively prevents corrosion. Equipped with externalinductors, ensure efhcient heat dissipation, which signifcantly improves the reliability and extends the life of the inverters.

Quick Arc Fault circuit interruption (Optional)

WIFl standard

Compact design

Multiple intelligent protections

Compatible with bifacial modules

String level monitoring

Product introduction

MPPT Range

Wide MPPT Range

PV OVERSIZE

1.5 Times PV Oversize

UNIBODY

One-piece Aluminum Housing

PROTECTION

Build-in SPD Type II

SMART

Smart IV Curve Scanning

UPDATE

Remote Firmware Update

Technical DataBNT003KTABNT004KTA BNT005KTA BNT006KTA BNT008KTA BNT010KTA BNT012KTA BNT015KTA
PV Input Data
Max. DC Power (W)510060007500900012000150001800022500
Max DC Voltage (V)750750750750750750750750
. MPPT Voltage Range(V)150-600150-600150-600150-600150-600150-600150-600150-600
MPPT Full Power Voltage Range (V)220-600220-600220-600220-600220-600220-600220-600330-600
Rated Input Voltage (V)380380380380380380400400
Start-up Voltage (V)150150150150150150150150
Max.Input Current(A)15x215x215x215x220+3232x232x232x2
Max.Short Current(A)25x225x225x225x230x4848x248x248x2
No.of MPP Tracker/No.of PV String2/22/22/22/22/32/42/42/4
Input Connector TypeMC4MC4MC4MC4MC4MC4MC4MC4
AC Output Data
Max.Output Power(VA)33004400550066008800110001320016500
Nominal Output Power (W)30004000500060008000100001200015000
Max. Output Current (A)10.513.51721.527303240
Nominal Output Voltage(V)3P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 2303P+N+PE/3P+PE 133/220 or 230
Grid Voltage Range180-260Vac (According to local standard)180-260Vac (According to local standard)180-260Vac (According to local standard)180-260Vac (According to local standard)180-260Vac (According to local standard)180-260Vac (According to local standard)180-260Vac (According to local standard)180-260Vac (According to local standard)
Nominal Output Frequency (Hz)50/6050/6050/6050/6050/6050/6050/6050/60
Grid Frequency Range45-55/55-65Hz (According to local standard)45-55/55-65Hz (According to local standard)45-55/55-65Hz (According to local standard)45-55/55-65Hz (According to local standard)45-55/55-65Hz (According to local standard)45-55/55-65Hz (According to local standard)45-55/55-65Hz (According to local standard)45-55/55-65Hz (According to local standard)
Output Power Factor1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)1 default (adjustable from 0.8 leading to 0.8 lagging)
Output Current THD<3%<3%<3%<3%<3%<3%<3%<3%
Efficiency
Max. Efficiency97.50%97.50%98.00%98.00%98.00%98.10%98.00%98.40%
Euro Efficiency97.00%97.00%97.40%97.50%97.50%97.50%97.80%97.80%
Protection
PV Reverse Polarity ProtectionYESYESYESYESYESYESYESYES
PV Insulation Resistance DetectionYESYESYESYESYESYESYESYES
AC Short Circuit ProtectionYESYESYESYESYESYESYESYES
AC Over Current ProtectionYESYESYESYESYESYESYESYES
AC Over Voltage ProtectionYESYESYESYESYESYESYESYES
Anti-Islanding ProtectionYESYESYESYESYESYESYESYES
Residual Current DetectionYESYESYESYESYESYESYESYES
Over Temperature ProtectionYESYESYESYESYESYESYESYES
Integrated DC switchYESYESYESYESYESYESYESYES
Surge ProtectionIntegrated (Type II)Integrated (Type II)Integrated (Type II)Integrated (Type II)Integrated (Type II)Integrated (Type II)Integrated (Type II)Integrated (Type II)
Smart IV Curve ScanningYESYESYESYESYESYESYESYES
Quick Arc Fault Circuit InterruptionOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional
General Data
Dimensions (WxHxD,mm)370x510x167370x510x192370x510x192370x510x192370x510x192370x535x192370x535x192370x535x192
Weight(kg)1616161617191919
Protection DegreeIP65IP65IP65IP65IP65IP65IP65IP65
Enclosure MaterialAluminumAluminumAluminumAluminumAluminumAluminumAluminumAluminum
Ambient Temperature Range (℃)-25-+60-25-+60-25-+60-25-+60-25-+60-25-+60-25-+60-25-+60
Humidity Range0-100%0-100%0-100%0-100%0-100%0-100%0-100%0-100%
TopologyTransformerlessTransformerlessTransformerlessTransformerlessTransformerlessTransformerlessTransformerlessTransformerless
Communication InterfaceRS485/WiFi/ Wire Ethernet/GPRS (optional)RS485/WiFi/ Wire Ethernet/GPRS (optional)RS485/WiFi/ Wire Ethernet/GPRS (optional)RS485/WiFi/ Wire Ethernet/GPRS (optional)RS485/WiFi/ Wire Ethernet/GPRS (optional)RS485/WiFi/ Wire Ethernet/GPRS (optional)RS485/WiFi/ Wire Ethernet/GPRS (optional)RS485/WiFi/ Wire Ethernet/GPRS (optional)
Cooling ConceptConvectionConvectionConvectionConvectionConvectionConvectionConvectionConvection
Night Power Consumption(W)<1<1<1<1<1<1<1<1
Max. Operation Altitude(m)20002000200020002000200020002000
Certifications and Standards
EMC StandardEN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12
Safety StandardIEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109IEC 60068, UL1741, EN62109
Grid-connectionIEEE1547, CSA C22,EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22,EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22,EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22,EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22,EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22,EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22,EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727IEEE1547, CSA C22,EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727